AD8302ARUZ-REEL 14-lead TSSOP – Analog Devices

RF detector with supply 2.7 V to 5.5 V, input frequency Low frequency to 2.7 GHz, and input level range -60 dBm to 0 dBm in a 50 Ω system.

Add to RFQ
SKU: AD8302ARUZ-REEL Category: Tag: Brand:
Questions about AD8302ARUZ-REEL 14-lead TSSOP – Analog Devices ?

Key Selection Information

Selection Parameter Confirmed Information
Function RF/IF gain/loss and phase detector
Input frequency Low frequency to 2.7 GHz
Input level range -60 dBm to 0 dBm in a 50 Ω system
Gain/loss measurement ±30 dB, 30 mV/dB
Phase measurement 0° to 180°, 10 mV/degree
Envelope bandwidth DC to 30 MHz
Supply voltage 2.7 V to 5.5 V
Package 14-lead TSSOP

Product Overview

The AD8302ARUZ-REEL is the tape-and-reel TSSOP version of Analog Devices’ integrated gain/loss and phase detector. It accepts two ac-coupled RF or IF inputs from low frequency to 2.7 GHz and provides simultaneous analog outputs representing relative magnitude and phase.

The device measures gain or loss over a ±30 dB range with 30 mV/dB scaling and phase from 0° to 180° with 10 mV/degree scaling. Because both inputs use matched demodulating log amplifiers, the part can compare two signal paths directly or operate in a feedback controller mode for gain/phase adjustment.

AD8302ARUZ-REEL product view

Technical Specifications

Parameter Confirmed Information
Measurement type Relative gain/loss and phase
Input frequency range LF to 2.7 GHz
Input level range -60 dBm to 0 dBm in 50 Ω system
Magnitude range ±30 dB
Magnitude scaling 30 mV/dB
Typical magnitude nonlinearity <0.5 dB
Phase range 0° to 180°
Phase scaling 10 mV/degree
Typical phase nonlinearity <1°
Small-signal envelope bandwidth DC to 30 MHz
Supply voltage 2.7 V to 5.5 V
Reference output 1.8 V
Package 14-lead TSSOP
Exact model lifecycle Production

Design Considerations

The phase output represents the phase difference between the two limited internal signal paths, so signal amplitude, matching and external path delay should be controlled when absolute accuracy matters. The stated phase and magnitude nonlinearities are typical specifications and should be used with the datasheet error curves for a precision instrument.

The 30 MHz envelope bandwidth is much lower than the RF input frequency. This is intentional: the AD8302 detects relative magnitude and phase of RF/IF carriers rather than digitizing the carrier waveform itself.

Related Engineering Resources

Quality & Verification Support

Third-party inspection or testing can be arranged according to customer requirements. Testing fees are borne by the buyer. Additional verification requirements can be discussed before shipment. After an order is placed, physical product, label, packaging, and Date Code photos may be provided where appropriate.