Device Overview

MID06W0505AGY-3R-Z is a MPS regulated isolated DC/DC converter in a SOICW-16 package. For substitution or design review, the strongest comparison points are Device Function (regulated isolated DC/DC converter), Input Voltage (4.5 to 5.5 V), Output Power (up to 0.6 W).

Selection-Critical Data

Parameter Confirmed Data Why It Matters
Device Function regulated isolated DC/DC converter Defines the device function or architecture that a compatible replacement must preserve before secondary ratings are compared.
Input Voltage 4.5 to 5.5 V Defines compatibility with the available system input rail and its operating range.
Output Power up to 0.6 W Defines available output-power headroom under the stated operating conditions; compare it at the same frequency, modulation/load and bias.
Isolation Voltage 3 kVDC Defines suppression of unwanted coupling between RF paths or switch states at the stated frequency.
Efficiency 53 % (maximum at full load) Defines conversion loss and therefore input-power demand and heat generation at the stated operating point.
Operating Temperature -40 to +125 degC Defines the qualified measurement or environmental range that the design must remain within.
Exact Package SOICW-16 Determines PCB footprint, pinout, mechanical assembly and orderable-variant compatibility.

Power-Management Selection Notes

At regulated isolated DC/DC converter, the device function defines the device function or architecture that a compatible replacement must preserve before secondary ratings are compared. The input voltage is 4.5 to 5.5 V; this defines compatibility with the available system input rail and its operating range.

53 % is the stated efficiency value. Defines conversion loss and therefore input-power demand and heat generation at the stated operating point. Technical condition: maximum at full load.

-40 to +125 degC is the stated operating temperature value. Defines the qualified measurement or environmental range that the design must remain within.

The exact package is SOICW-16; this determines PCB footprint, pinout, mechanical assembly and orderable-variant compatibility.

The output power is up to 0.6 W; this defines available output-power headroom under the stated operating conditions; compare it at the same frequency, modulation/load and bias. At 3 kVDC, the isolation voltage defines suppression of unwanted coupling between RF paths or switch states at the stated frequency.

Package

SOICW-16