AD8317ACPZ-R7 8-lead LFCSP, 3 × 2 mm – Analog Devices

RF detector with frequency range 1 MHz to 10 GHz useful operation and accurate log conformance To 8 GHz.

Add to RFQ
SKU: AD8317ACPZ-R7 Category: Tag: Brand:
Questions about AD8317ACPZ-R7 8-lead LFCSP, 3 × 2 mm – Analog Devices ?

Key Selection Information

Selection Parameter Confirmed Information
Function Logarithmic RF detector/controller
Frequency range 1 MHz to 10 GHz useful operation
Accurate log conformance To 8 GHz
Dynamic range 55 dB with <±3 dB error through 8 GHz
Log slope Approximately -22 mV/dB
Pulse response 6 ns / 10 ns fall/rise
Supply 3.0 V to 5.5 V at 22 mA
Package 8-lead LFCSP, 3 × 2 mm

Product Overview

The AD8317ACPZ-R7 is a compact wideband logarithmic detector/controller that extends useful RF power detection from 1 MHz to 10 GHz. Its progressive-compression architecture provides a decibel-scaled output and supports both measurement and closed-loop RF power-control applications.

The part’s key selection point is bandwidth combined with fast response. Analog Devices specifies accurate logarithmic conformance through 8 GHz, useful operation to 10 GHz, and a 55 dB input range with less than ±3 dB error through 8 GHz. Pulse response of approximately 6 ns falling and 10 ns rising makes it suitable for fast RF-burst detection where slower power detectors would average away the event.

AD8317ACPZ-R7 product view

Technical Specifications

Parameter Confirmed Information
Detector type Demodulating logarithmic amplifier
Frequency range 1 MHz to 10 GHz useful operation
Accurate logarithmic range To 8 GHz
Dynamic range 55 dB with <±3 dB error through 8 GHz
High-accuracy behavior ±1 dB over documented range and temperature
Log slope Approximately -22 mV/dB
Pulse response 6 ns / 10 ns fall/rise
Supply voltage 3.0 V to 5.5 V
Supply current 22 mA
Disabled current About 200 µA
Operating temperature -40°C to +85°C
Package 8-lead LFCSP, 3 × 2 × 0.75 mm with exposed pad
Product status Production

Design Considerations

The useful 10 GHz headline should not be confused with uniform log accuracy to 10 GHz. For calibrated power measurement above 8 GHz, review the exact frequency-dependent error and intercept curves rather than applying lower-frequency calibration constants unchanged.

Fast response also increases output-noise bandwidth. Choose any external output filtering from the required burst response and measurement noise floor together; excessive filtering removes the speed advantage, while too little filtering can degrade ADC stability.

Related Engineering Resources

Quality & Verification Support

Third-party inspection or testing can be arranged according to customer requirements. Testing fees are borne by the buyer. Additional verification requirements can be discussed before shipment. After an order is placed, physical product, label, packaging, and Date Code photos may be provided where appropriate.

Request a Quote

To request a quotation, provide the manufacturer part number, required quantity, destination, target Date Code if applicable, and any testing or inspection requirements.

Package

8-lead LFCSP, 3 × 2 mm