AD8313ARMZ-REEL7 8-lead MSOP – Analog Devices

RF detector with frequency range 0.1 GHz to 2.5 GHz, supply 2.7 V to 5.5 V, and dynamic range 70 dB to ±3 dB.

Add to RFQ
SKU: AD8313ARMZ-REEL7 Category: Tag: Brand:
Questions about AD8313ARMZ-REEL7 8-lead MSOP – Analog Devices ?

Key Selection Information

Selection Parameter Confirmed Information
Function Demodulating logarithmic detector/controller
Frequency range 0.1 GHz to 2.5 GHz
Dynamic range 70 dB to ±3 dB
High-accuracy range ±1 dB over 65 dB at 1.9 GHz
Full-scale response About 40 ns typical
Supply voltage 2.7 V to 5.5 V
Typical current 13.7 mA at 3 V
Package 8-lead MSOP

Product Overview

The AD8313ARMZ-REEL7 is the tape-and-reel 8-lead MSOP version of Analog Devices’ AD8313 logarithmic RF detector/controller. It converts RF input level into a decibel-scaled output voltage from 100 MHz to 2.5 GHz and can also be used inside a feedback loop to regulate an RF amplifier.

A major selection advantage is the wide logarithmic range: Analog Devices specifies 70 dB dynamic range to ±3 dB and ±1 dB accuracy over 65 dB at 1.9 GHz. This makes the part useful for received-signal-strength measurement or transmitter power control where logarithmic response over several decades matters more than true-rms waveform independence.

AD8313ARMZ-REEL7 product view

Technical Specifications

Parameter Confirmed Information
Detector type Demodulating logarithmic amplifier
Frequency range 0.1 GHz to 2.5 GHz
Dynamic range 70 dB to ±3 dB
Accuracy range at 1.9 GHz ±1 dB over 65 dB
Typical full-scale response 40 ns
Supply voltage 2.7 V to 5.5 V
Typical current at 3 V 13.7 mA
Power-down current About 20 µA
Operating temperature -40°C to +85°C
Package 8-lead MSOP
Product status Production

Design Considerations

The logarithmic transfer function is frequency dependent, so intercept and slope calibration should be based on the actual operating band when absolute power accuracy matters. A system that spans multiple bands may need frequency-specific calibration constants.

The AD8313 measures logarithmic envelope power rather than true rms power. Complex modulation with changing crest factor can therefore produce a different result from a TruPwr detector such as AD8361 or AD8362, even when the average RF power is the same.

Related Engineering Resources

Quality & Verification Support

Third-party inspection or testing can be arranged according to customer requirements. Testing fees are borne by the buyer. Additional verification requirements can be discussed before shipment. After an order is placed, physical product, label, packaging, and Date Code photos may be provided where appropriate.

Request a Quote

To request a quotation, provide the manufacturer part number, required quantity, destination, target Date Code if applicable, and any testing or inspection requirements.

Package