ADL5501AKSZ-R7 6-lead SC70 – Analog Devices

RF detector with frequency range 50 MHz to 6 GHz, supply 2.7 V to 5.5 V, and conversion gain 6.3 V/V rms at 900 MHz.

Add to RFQ
SKU: ADL5501AKSZ-R7 Category: Tag: Brand:
Questions about ADL5501AKSZ-R7 6-lead SC70 – Analog Devices ?

Key Selection Information

Selection Parameter Confirmed Information
Function TruPwr RF power detector
Frequency range 50 MHz to 6 GHz
Input dynamic range Up to 30 dB
Input impedance 50 Ω nominal
Maximum input 1.25 V rms / 15 dBm
Conversion gain 6.3 V/V rms at 900 MHz
Supply voltage 2.7 V to 5.5 V
Package 6-lead SC70

Product Overview

The ADL5501AKSZ-R7 is a compact SC70 true-power detector for RF signal chains from 50 MHz to 6 GHz. It presents a nominal 50 Ω ac-coupled input and produces a linear dc output proportional to rms input voltage, allowing measurement of both simple carriers and complex high-crest-factor modulation.

Its selection advantage is low power and small package size. Analog Devices specifies only 3.3 mW consumption from a 3 V supply, with up to 30 dB input dynamic range and 15 dBm maximum input. At 900 MHz, the output conversion gain is 6.3 V/V rms.

ADL5501AKSZ-R7 product view

Technical Specifications

Parameter Confirmed Information
Detector response TruPwr / rms power
Frequency range 50 MHz to 6 GHz
Input dynamic range Up to 30 dB
Nominal input impedance 50 Ω
Maximum input 1.25 V rms / 15 dBm
Output response Linear dc voltage
Conversion gain at 900 MHz 6.3 V/V rms
Supply voltage 2.7 V to 5.5 V
Power consumption at 3 V 3.3 mW
Package 6-lead SC70
Product status Production

Design Considerations

The 6.3 V/V conversion gain is specified at 900 MHz and should not be treated as frequency invariant. For a multi-band power monitor, use calibration data at the intended carrier frequency to remove RF-path and detector gain variation.

The SC70 package keeps board area and power low, but output filtering still sets the tradeoff between measurement noise and response time. Choose the filter from the modulation envelope the system must average.

Related Engineering Resources

Quality & Verification Support

Third-party inspection or testing can be arranged according to customer requirements. Testing fees are borne by the buyer. Additional verification requirements can be discussed before shipment. After an order is placed, physical product, label, packaging, and Date Code photos may be provided where appropriate.

Request a Quote

To request a quotation, provide the manufacturer part number, required quantity, destination, target Date Code if applicable, and any testing or inspection requirements.

Package